Specifications: MiniMax XP
Gases Detected:   Alarm Set Points
  Range level1 level2 STEL TWA
Oxygen (02) 0 to 30% v/v 23.5% v/v 19.5% v/v n/a n/a
Carbon Monoxide (CO) 0 to 999 ppm 35 ppm 100 ppm 400 ppm 35 ppm
Hydrogen Sulfide (H2S) 0 to 250 ppm 10 ppm 15 ppm 15 ppm 10 ppm
Sulfur Dioxide (SO2) 0 to 150 ppm 2 ppm 5 ppm 5 ppm 2 ppm
Chlorine (Cl2) 0 to 50 ppm 0.5 ppm 1 ppm 1 ppm 0.5 ppm
Hydrogen Cyanide (HCN) 0 to 100 ppm 5 ppm 10 ppm 10 ppm 5 ppm
Nitrogen Dioxide (NO2 ) 0 to 150 ppm 3 ppm 5 ppm 5 ppm 3 ppm
Ammonia (NH3 ) 0 to 100 ppm 25 ppm 50 ppm 35 ppm 25 ppm
Hydrogen (H2) 0 to 999 ppm 100 ppm 500 ppm n/a n/a
General: Serviceable, portable single gas monitor for personal protection against Oxygen and toxic gas hazards
Calibration: Time between calibrations is maximized utilizing cell decay compensation facility. The maximum time between calibrations is 12 months #
Operating Life: Sensor (replaceable) Minimum of 2 years
Battery (replaceable) 3 years*
Operating Temperature: -20°C to +50°C (-4°F to +122°F) (temperature compensated)
Humidity: 5-95% RH (non-condensing)
Audible Alarm: 95dB @ 10cm (3.9”)
Visual Alarm: High intensity Red LEDs
Vibrating Alarm: Standard
Display: Ultra clear backlit LCD displays gas levels & instrument status
Sensor Type: Electrochemical (replaceable)
Battery Type: Lithium CR2, 3.0v (replaceable)
Diagnostics: Self-test of circuitry, battery, LCD, and software.
Sensor test using patented Reflex † sensor technology
IP Rating: IP54 (minimum)
Intrinsic Safety: North America: Class 1, Div 1, Groups A, B, C, D, T4 (UL/cUL)
Europe: EEx ia IIB T4 (CENELEC) II 2G EEx ia IIC T4 (ATEX pending)
RFI/EMC: CE EN50270:1999 and EN55011
Dimensions: 93mm (H) x 50mm (W) x 27mm(D)
(3.6” x 2” x 1.1”) excluding clip
Weight: Toxic
Oxygen
81.5g (2.8oz)
93.0g (3.3oz)