| Specifications: |
MiniMax X4
|
| Gases Detected: |
|
Alarm Set Points |
| |
Range |
level1 |
level2 |
STEL |
TWA |
| Flammable (Exp) |
0 to 100% LEL* |
10% LEL |
20% LEL |
n/a |
n/a |
| Oxygen (O2) |
0 to 30% vol |
23.5% vol |
19.5% vol |
n/a |
n/a |
| Carbon Monoxide (CO) |
0 to 999 ppm |
35 ppm |
100 ppm |
100 ppm |
35 ppm |
| Hydrogen Sulfide (H2S) |
0 to 250 ppm |
10 ppm |
15 ppm |
15 ppm |
10 ppm |
|
* Flammable channel can display gas
concentration in %vol units for a range of flammable gases
# User configurable |
| Sensors |
Patented SurecellTM electrochemical
and catalytic bead sensing technology for stable and reliable
performance in all industrial environments. |
| Diagnostics |
Self-test of circuitry, battery,
LCD, and sensors on start up or on demand. Patented ReflexTM
cell check techniques included as standard for toxic channels. |
| Display |
Ultra clear icon driven backlit
LCD displays gas level and detector status. Unique ‘flip
display’ function at the press of a button for added user
convenience. High/Low Peak hold
facility included with user clear. Time and date. |
| User Interface |
Intuitive three
button operation for detector configuration. |
| Audible Alarm |
90 db @ 30 cm |
| Visual Alarm |
High intensity
red LEDs combined with red backlight for maximum effect. |
| Vibrating Alarm |
Supplied as standard. |
| Operating Temperature |
-20°C to
+50°C (-4°F to +122°F).
TempraSURETM temperature compensation. |
| Humidity |
5-95% RH (non-condensing). |
| IP Rating |
Ingress protection to IP65. |
| Approvals |
North America: Class I, Div 1,
Groups A, B, C, D T4.
Europe: ATEX II 2G EEx ia d IIC T4 - PENDING |
| RFI/EMC |
CE EN50270:1999 and EN55011. |
| Sensor Life |
Minimum of 2 years backed by inclusive
2 year warranty. |
| Battery Life |
14-16 hours with 2 x AA Alkaline
batteries.
Low power audiovisual warning. |
| Dimensions |
124 mm(H) X 76 mm(W) X 36 mm(D). |
| Weight |
210 g (without batteries), 258
g (with batteries) |
| Warranty |
2 years |
| |