Overview
Features
Specifications
Parts & Accessories
Models
Downloads
 
MicroMAX PRO
MicroMAX
Impact / Impact PRO
MiniMAX4
Enforcer
Safelink
Tetra
Tetra : 3
Triple Plus +
Detective +
Specifications
Mechanical Dimensions   4.75”W x 3”H x 1.8”D
Mechanical Weight   Internal pump models: < 16 oz. Diffusion models: < 15 oz
Operating Temperature Range   -20°C to +50°C (-4°F to +122°F)
Relative Humidity Range   0 to 98% (non condensing)
Power Sources Rechargeable NiCad battery pack or 2 AA sized alkaline batteries
Battery Life Internal pump models: 8 hours. Diffusion models: 10 hours
Alarm Outputs Audible: > 90 dB at 1’ Visual: Red LED, flashing display characters
Approvals UL classified and CSA certified Class I, Division 1, Groups A, B, C, D Class II option–UL classified
Warranty Lifetime. Excludes sensors, batteries and pump
Repeatability + 2%
   
Gas Ranges & Alarm Set Points Sensor Instrument Range Immediate Alarm Accuracy
  Combustible (LEL) 0-100% LEL 10% LEL 2% LEL or
5% FS
  Oxygen (O2) 0-25% by volume 19.5%(low)23.5%(high) 0.5% by volume
  Carbon Monoxide (CO) 0-800 PPM 35 PPM(25 PPM in CA) + 10% of reading
  Hydrogen Sulfide (H2S) 0-500 PPM 10 PPM + 10% of reading
  Sulfur Dioxide (SO2) 0-20 PPM 2 PPM + 10% of reading
  Hydrogen Cyanide (HCN) 0-800 PPM 5 PPM + 10% of reading
  Phosphine (PH3) 0-20 PPM 0.3 PPM + 10% of reading
  Ammonia (NH3) 0-500 PPM 25 PPM + 10% of reading
  Chlorine (Cl2) 0-100 PPM 0.5 PPM + 10% of reading
  Chlorine Dioxide (ClO2) 0-10 PPM 0.1 PPM + 10% of reading
  Combo Tox (CO/H2S) 0-800 PPM 35/15 PPM + 10% of reading
Models  
Number of Gases Pump Model Combust-ible LEL Oxygen
O2
Carbon Monoxide CO Hydrogen Sulfide
H2S
Ammonia
NH3
Chlorine
Cl2
Chlorine Dioxide ClO2 Phos-phine
PH3
5 Gases MAX-5ATP      
  MAX-5BTP      
  MAX-5CTP      
  MAX-5ETP      
4 Gases MAX-4AP        
  MAX-4DP        
  MAX-4EP        
  MAX-4HP      
3 Gases MAX-3DP          
  MAX-3EP          
2 Gases MAX-2GP            
  MAX-2HP            
1 Gas MAX-2GP              
  MAX-1DP